Ultra-Low Turbidity Water Sensor |Flow-through Mounting
- Laser Precision: Auto-intensity correction ensures <0.1NTU error, 80% more stable than LED-based sensors.
- Zero Maintenance: Self-cleaning wiper extends service interval to 2 years, ideal for water plants.
- Cloud & Local Control: Modbus/RS485 connectivity and WQS cloud enable remote alerts and data analytics.
- Plug-and-Play: Pre-calibrated, 10-minute setup for rapid deployment.
Overview
Laser-based ultra-low turbidity sensor with 90° scattered light technology, achieving <0.1NTU error at <1NTU range. Features self-cleaning optics for tap water applications, paired with DL-W-S transmitter and WQS cloud for real-time local/remote monitoring.
Common applications include drinking water treatment plants monitoring filter effluent turbidity below 0.1 NTU, pharmaceutical water-for-injection (WFI) systems, semiconductor ultrapure water systems, and power plant condensate polishing.
For sensor comparison, consult our water quality sensor selection guide. This sensor complements our standard turbidity sensor for medium-range and high-range turbidity monitoring needs.
UL-TUR-P
| Principle | 90° scattering method |
| Dimension | 150×82×175 mm |
| Power requirements | DC+12 V ~ +24 V |
| Measurement period | 10 seconds to 65535 seconds |
| Operating temperature | 0 to 50 °C |
| Pressure | 10 bar |
| Power | <6W |
| Cleaning method | Cleaning brush |
| Sample flow rate | 200-500m L/min |
| Communication | RS485(Modbus RTU) |
| Parameter | TUR |
| Model No. | WQS-T-SC3 |
| Range | 0-100 NTU/FNU |
| Resolution | 0.001 NTU |
| Accuracy | ±2% or ±0.015 |